MARC details
| 000 -LEADER |
| fixed length control field |
03356ntm a2200349 i 4500 |
| 001 - CONTROL NUMBER |
| control field |
12102116 |
| 005 - DATE AND TIME OF LATEST TRANSACTION |
| control field |
20231004105132.0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
| fixed length control field |
150118s2023 ua a f bm 000 0 eng | |
| 040 ## - CATALOGING SOURCE |
| Original cataloging agency |
EG-EULC |
| Transcribing agency |
EG-EULC |
| Description conventions |
rda |
| 041 0# - LANGUAGE CODE |
| Language code of text/sound track or separate title |
eng |
| Language code of summary or abstract/overprinted title or subtitle |
ara |
| 082 04 - DEWEY DECIMAL CLASSIFICATION NUMBER |
| Item number |
E.A.E |
| Edition number |
22 |
| Classification number |
617.692 |
| 100 1# - MAIN ENTRY--PERSONAL NAME |
| Personal name |
Elghazally, Ahmed Safwat Amin, |
| Relator term |
author |
| 9 (RLIN) |
34036 |
| 245 10 - TITLE STATEMENT |
| Title |
Effect of scan body design on the accuracy of the implant position in implant supported prosthesis / |
| Statement of responsibility, etc |
Submitted by Ahmed Safwat Amin Elghazally, (B.D.S. Faculty of Oral and Dental Medicine, Future University in Egypt, 2017); Supervision by Prof. Hussien ElCharkawi, Professor and head of Prosthodontics department, Faculty of Oral & Dental Medicine, Future University in Egypt, Prof. Amro Hosny, Professor of Prosthodontics, Faculty of Dentistry, Cairo University in Egypt, Ass. Prof. Bassem Mohsen, Associate professor of Prosthodontics, Faculty of Oral & Dental Medicine, Future University in Egypt |
| 246 15 - VARYING FORM OF TITLE |
| Title proper/short title |
تأثير تصميم أجسام المسح علي دقة نقل وضع الغرسات تحت التركيبات المحملة عليها |
| 264 #1 - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT) |
| Date of publication, distribution, etc |
2023 |
| 300 ## - PHYSICAL DESCRIPTION |
| Extent |
vi, 74 pages, 3 pages : |
| Other physical details |
color illustrations; |
| Dimensions |
22 cm |
| 336 ## - CONTENT TYPE |
| Source |
rdacontent |
| Content type term |
text |
| 337 ## - MEDIA TYPE |
| Source |
rdamedia |
| Media type term |
unmediated |
| 338 ## - CARRIER TYPE |
| Source |
rdacarrier |
| Carrier type term |
volume |
| 500 ## - GENERAL NOTE |
| General note |
Submitted by Ahmed Safwat Amin Elghazally, (B.D.S. Faculty of Oral and Dental Medicine, Future University in Egypt, 2017); Supervision by Prof. Hussien ElCharkawi, Professor and head of Prosthodontics department, Faculty of Oral & Dental Medicine, Future University in Egypt, Prof. Amro Hosny, Professor of Prosthodontics, Faculty of Dentistry, Cairo University in Egypt, Ass. Prof. Bassem Mohsen, Associate professor of Prosthodontics, Faculty of Oral & Dental Medicine, Future University in Egypt |
| 502 ## - DISSERTATION NOTE |
| Dissertation note |
Thesis (M.Sc.)-Future University in Egypt, Faculty of Oral and Dental Medicine, Department of prosthodontics Department, 2023. |
| 504 ## - BIBLIOGRAPHY, ETC. NOTE |
| Bibliography, etc |
Includes bibliographical references. |
| 520 3# - SUMMARY, ETC. |
| Summary, etc |
Effect of Scan body Design on the Accuracy of the Implant<br/>Position in Implant Supported Prosthesis<br/>This study was conducted to evaluate the accuracy of two types of scan body to<br/>evaluate the accuracy of digital impression of implant.<br/>In this study a resin model was fabricated and four implant was inserted in the canine<br/>and molar area both sides and four standardized long scan bodies were inserted on the<br/>top of implant to make the basic reference digital impression then the four long scan<br/>bodies were replaced by four short scannable healing abutment and scanning was done<br/>then four plastic caps were added above short scannable healing abutment to modify<br/>short scan body and scanning was done.<br/>The comparison between two types of scan bodies was digitally done and the results<br/>showed acceptable high accuracy for both types of scan bodies, however the accuracy<br/>of scannable healing abutment with plastic cap was higher than scannable healing<br/>abutment without plastic cap. |
| 546 ## - LANGUAGE NOTE |
| Language note |
Text in English, abstracts in English and Arabic. |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name as entry element |
Prosthodontics |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name as entry element |
Bridges (Dentistry) |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name as entry element |
Crowns (Dentistry) |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
| Topical term or geographic name as entry element |
Dentures |
| 856 40 - ELECTRONIC LOCATION AND ACCESS |
| Materials specified |
DSpace electronic resources |
| Uniform Resource Identifier |
<a href="http://repository.fue.edu.eg/xmlui/handle/123456789/5779">http://repository.fue.edu.eg/xmlui/handle/123456789/5779</a> |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) |
| Koha item type |
Thesis |
| Source of classification or shelving scheme |
Dewey Decimal Classification |