Ramdan Hours:
Sun - Thu
9.30 AM - 2.30 PM
Iftar in --:--:--
🌙 Maghrib: --:--

Comparison of stress pattern and retention between two telescopic abutment convergence angle retaining an overdenture / (Record no. 5801)

MARC details
000 -LEADER
fixed length control field 03722nam a22003857i 4500
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 120326s2008 ua a | bm 00| 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EG-NcFUE
Description conventions rda
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
Language code of summary or abstract/overprinted title or subtitle ara
082 04 - DEWEY DECIMAL CLASSIFICATION NUMBER
Classification number 617.69
Item number A.N.C
Edition number 21
100 1# - MAIN ENTRY--PERSONAL NAME
Personal name Abdel Nabi,Nouran Mahmoud
Relator term author
245 14 - TITLE STATEMENT
Title Comparison of stress pattern and retention between two telescopic abutment convergence angle retaining an<br/>overdenture /
Statement of responsibility, etc By Nouran Mahmoud Abdel Nabi; supervised by Ashraf Abdel Monaem Amer, Maha Wagdy.
246 15 - VARYING FORM OF TITLE
Title proper/short title مقارنة اﻻجهاد وقوة اﻹلقاء ﻻثنين من زوايا اﻹلتقاء التلسكوبية ﻻستبقاء اﻷطقم الفوقية
264 #1 - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT)
Date of publication, distribution, etc 2008
300 ## - PHYSICAL DESCRIPTION
Extent 155 pages :
Other physical details illustrations ;
Dimensions 30 cm
336 ## - CONTENT TYPE
Content type term text
336 ## - CONTENT TYPE
Source rdacontent
337 ## - MEDIA TYPE
Media type term unmediated
337 ## - MEDIA TYPE
Source rdamedia
338 ## - CARRIER TYPE
Carrier type term volume
338 ## - CARRIER TYPE
Source rdacarrier
500 ## - GENERAL NOTE
General note Supervisors: Ashraf Abdel Monaem Amer, Maha Wagdy
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M. Sc.)-Cairo University, Faculty of Oral and Dental Medicine, 2008.
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc Includes bibliographical references (pages 125-155)<br/>
520 ## - SUMMARY, ETC.
Summary, etc This in vitro study was performed to compare and evaluate the stress distribution patterns and retention of two telescopic abutment designs with convergence angles 4° and 6° in implant supported overdentures using strain gauge technology. An acrylic resin test model representing a completely edentulous lower arch was used. The distal part of the residual ridge was covered with silicon based soft liner to simulate the mucoperiosteum. Using a dental surveyor, four root shaped implants were installed in the inter-foraminal area, parallel to each other. A prosthesis with a metal framework specially designed for loading the implants, and testing the retention, was constructed. The model was prepared to receive eight strain gauges distributed around the implants. An index was fabricated to fix the relation between the prosthesis and the model during picking-up procedures of the telescopic caps. Abutments with 4° convergence angle were fastened to the implants and their caps were picked up in the prosthesis with self-cured acrylic resin.
520 ## - SUMMARY, ETC.
Summary, etc A universal testing machine was used to test the prosthesis retention. Vertical and oblique loads (50- 70) Newton was applied at the right first molar area then at the right canine area, and strains developed at the four implants were recorded. The retention and loading experiments were repeated with the 6° convergence angle replacing the 4° convergence angle abutments. Each experiment was repeated ten times then the mean values were tabulated and statistically analyzed. The results of this study showed that the mean retention with telescope angle 4° was significantly higher than that of telescope angle 6°. When load was applied at the cantilever the most distal implant received the highest stresses. The angle of convergence influences the transfer of stresses to the implant. When load was applied at the cantilever, implant with Telescope angle 4°received higher stresses than with Telescope angle 6°. While when the load was applied between the implants, the angle of convergence had no effect on the amount of stresses transferred to the implants.
546 ## - LANGUAGE NOTE
Language note Text in English; abstracts in English and Arabic
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name as entry element overdenture.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name as entry element retention.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name as entry element telescopic.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name as entry element stress pattern.
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Wagdy, Maha
9 (RLIN) 26769
Relator term supervisor
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Amer, Ashraf Abdel Monaem
9 (RLIN) 26770
Relator term supervisor
856 40 - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier http://main.eulc.edu.eg/eulc_v5/Libraries/Thesis/BrowseThesisPages.aspx?fn=ThesisPicBody&BibID=10874365&TotalNoOfRecord=14&PageNo=1&PageDirection=First
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Item type Thesis
Holdings
Lost status Source of classification or shelving scheme Damaged status Not for loan Collection code Home library Current library Shelving location Date acquired Total Checkouts Full call number Barcode Date last seen Price effective from Koha item type
  Dewey Decimal Classification     Dental sciences ( General ) Main library Main library C4 THESIS 02/04/2012   617.69 A.N.C 00008010 20/02/2025 02/04/2012 Thesis