Ramdan Hours:
Sun - Thu
9.30 AM - 2.30 PM
Iftar in --:--:--
🌙 Maghrib: --:--
Image from Google Jackets

Effect of low-level diode laser bio-stimulation on osseointegration in vivo before, during and after immediate implants in mandibular molars : A randomized clinical study / submitted byAhmed El Sayed Fahim El Sayed, B.D.S. Future University (2016)

By: Material type: TextTextLanguage: English Summary language: Arabic Publisher: 2022Description: 67 pages, 2 pages : illustrations (some color) ; 24 cmContent type:
  • text
Media type:
  • unmediated
Carrier type:
  • volume
Other title:
  • تأثير التحفيز الحيوي بليزر الصمام الثنائي منخفض المستوى على الاندماج العظمي في الجسم الحي قبل وأثناء وبعد الغرسات المباشرة في الأضراس السفلية : تجارب سريرية عشوائية [Added title page title]
Subject(s): DDC classification:
  • 22 617.69 E.A.E
Online resources: Dissertation note: Thesis (M.Sc.)-Future University, Faculty of Oral and Dental Medicine, Department of Oral & Maxillofacial Surgery, 2022. Abstract: Aim of the study The aim of the study is to evaluate the effect of low-level diode laser bio-stimulation on osseointegration when applied before, after and during immediate implantation in vivo.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Collection Call number Status Date due Barcode
Thesis Thesis Main library C4 THESIS Dental ( Oral & Maxillofacial Surgery ) 617.69 E.A.E (Browse shelf(Opens below)) Not for loan 00016617
Browsing Main library shelves, Shelving location: C4 THESIS Close shelf browser (Hides shelf browser)
No cover image available No cover image available No cover image available No cover image available No cover image available No cover image available No cover image available
617.69 A.N.C Comparison of stress pattern and retention between two telescopic abutment convergence angle retaining an overdenture / 617.69 B.M.E Effect of retained coronal dentine lovcation on the fracture resistance of endodontically treated teeth restord with two recent post systems / 617.69 D.K.E The effect of three attachment types on the retention characteristics and load distribution in implant supported mandibular overdentures : (In-vitro study) / 617.69 E.A.E Effect of low-level diode laser bio-stimulation on osseointegration in vivo before, during and after immediate implants in mandibular molars : A randomized clinical study / 617.69 E.R.E Effect of Artificial Aging on Hardness and Surface Roughness of Two Types of Zirconia (In-Vitro Study) : Submitted to the Faculty of Oral and Dental Medicine, Future University in Egypt In Partial Fulfillment of the Requirement for Master Degree In Fixed Prosthodontics / 617.69 H.A.A Assessment of vertical bone gain and neurosensory affection in computer guided vs sandwich osteotomy technique in the atrophied posterior mandible : a randomized clinical trial / 617.69 M.A.E Effect of different surface treatments on Bond Strength to Tetragonal and Cubic Zirconia /

Prof. Dr. Ahmed Farid Shehab (Professor of Oral & Maxillofacial Surgery Department, Vice dean of environmental affairs and community service, Faculty of Oral and Dental Medicine, Future University in Egypt), Prof. Dr. Waleed Ragab Radwan El-bialy (Professor of Oral & Maxillofacial Surgery, Faculty of Dentistry, Cairo University), Dr. Ahmed Kamal Abu Zekry (Lecturer of Oral& Maxillofacial Surgery, Faculty of Oral and Dental Medicine, Future University in Egypt).

Thesis (M.Sc.)-Future University, Faculty of Oral and Dental Medicine, Department of Oral & Maxillofacial Surgery, 2022.

Includes bibliographical references.

Aim of the study
The aim of the study is to evaluate the effect of low-level diode
laser bio-stimulation on osseointegration when applied before, after and during immediate implantation in vivo.

Text in English, abstracts in English and Arabic.

There are no comments on this title.

to post a comment.