The effect of nanoparticles incorporation on antimicrobial and bond strength properties of bio-ceramic sealer : an in vitro study / By Hatem Tarek Salah Eldeen, B.D.S 2017, Faculty of Oral and Dental Medicine, Future University in Egypt
Material type:
TextLanguage: English Summary language: Arabic Publisher: 2023Description: 115 pages, 3 pages : illustrations (mostly color) ; 30 cmContent type: - text
- unmediated
- volume
- تأثير دمج الجسيمات النانوية على خصائص مقاومة الميكروبات وقوة الرابطة للسداد الخزفي الحيوي : دراسة خارج الجسم الحي [Added title page title]
- 22 617.6342 S.H.E
| Item type | Current library | Call number | Status | Date due | Barcode | |
|---|---|---|---|---|---|---|
Thesis
|
Main library C4 THESIS | 617.6342 S.H.E (Browse shelf(Opens below)) | Not for loan | 00017268 |
Browsing Main library shelves, Shelving location: C4 THESIS Close shelf browser (Hides shelf browser)
Supervisors, Prof. Wael Hussein Kamel, Professor and Head of Endodontic Department, Faculty of Oral and Dental medicine, Future University in Egypt, Prof. Nehal Ezzat Sabet, Professor of Endodontics, Faculty of Dentistry, Cairo university, Dr. Adel Abdelwahed, Associate professor in Endodontics, Faculty of Oral and Dental medicine, Future University in Egypt
Thesis (M.Sc.)-Future University, Faculty of Oral and Dental Medicine, Department of Endodontics, 2023.
Includes bibliographical references.
AH Plus sealer had higher antibacterial effect than Bio-C sealer. The incorporation of bioactive glass nanoparticles improves the antibacterial activity of AH Plus and Bio-C sealer at different time intervals. As regard to the resin-based sealer (AH plus) with or without incoprporation of bioactive glass nanoparticles the highest antibacterial efficacy was recorded at 1 hour while the lowest antibacterial efficacy was recorded after 1 month. As regard to the bioceramic based sealer (Bio-C) with or without incoprporation of bioactive glass nanoparticles the highest antibacterial efficacy was recorded after 1 week while the lowest antibacterial efficacy was recorded after 1 month
Regarding the tested root canal sealers, Bio-C with nanoparticles showed the highest push out bond strength compared to other groups followed by bio-c, AH plus with nanoparticles and the least bond strength was AH plus
Regarding the sections of the roots, the apical one third showed a significantly lower values in all groups compared to both the middle and coronal thirds, while no significant differences were found between the values of the middle and coronal thirds in all groups
Regarding the mode of failure, all tested groups showed significant higher percentage of cohesive failure compared to adhesive and mixed failures