000 05073cam a2200481 i 4500
999 _c11909
_d11909
001 18459636
005 20201220140529.0
008 150122t20152015ne a b 001 0 eng c
010 _a 2015931607
016 7 _a101662177
_2DNLM
020 _a9780128007747
020 _a0128007745
035 _a(OCoLC)ocn866615499
040 _aNLM
_beng
_cEG-NcFUE
_erda
_dBTCTA
_dYDXCP
_dVRC
_dOCLCF
_dCUD
_dDLC
042 _apcc
050 0 0 _aR857.T7
_bB86 2015
060 0 0 _a2015 F-904
060 1 0 _aQT 36
082 0 0 _a610.28
_223
_bB.V.P
100 1 _aButton, Vera Lucia da Silveira Nantes,
_eauthor.
245 1 0 _aPrinciples of measurement and transduction of biomedical variables /
_cVera Lucia da Silveira Nantes Button, Department of Biomedical Engineering, School of Electrical and Computing Engineering, University of Campinas, Sao Paulo, Brazil.
264 1 _aAmsterdam ;
_aNew York :
_bElsevier/AP, Academic Press is an imprint of Elsevier,
_c[2015]
264 4 _cc2015
300 _ax, 370 pages :
_billustrations ;
_c24 cm
336 _atext
_btxt
_2rdacontent
337 _aunmediated
_bn
_2rdamedia
338 _avolume
_bnc
_2rdacarrier
504 _aIncludes bibliographical references and index.
505 0 0 _aront Cover; Principles of Measurement and Transduction of Biomedical Variables; Copyright Page; Dedication; Contents; Preface; 1 Introduction to Biomedical Variables Transducing; 1.1 Introduction; 1.2 Characteristics of Transducers; 1.2.1 Static characteristics of transducers; 1.2.1.1 Static sensitivity; 1.2.1.2 Linearity; 1.2.1.3 Input range; 1.2.1.4 Accuracy, resolution, threshold, and precision; 1.2.1.5 Repeatability and reproducibility; 1.2.1.6 Hysteresis; 1.2.1.7 Saturation; 1.2.2 Dynamic characteristics of transducers; 1.2.2.1 Dynamic variables. 1.2.2.2 Linear ordinary time invariant system1.2.2.3 Zero-order, first-order and second-order systems; 1.2.2.4 Time delay; Recommended Readings; 2 Electrodes for Biopotential Recording and Tissue Stimulation; 2.1 Introduction; 2.2 Biopotentials; 2.3 Electrode-Electrolyte Interface; 2.3.1 Half-cell potential (Vhc); 2.3.1.1 Hydrogen reference electrode; 2.3.1.2 Ag-AgCl reference electrode; 2.3.1.3 Calomel reference electrode; 2.3.2 Equivalent electronic circuit of the electrode/electrolyte interface; 2.4 Electrolyte-Skin Interface; 2.5 Artifacts of Measurement; 2.5.1 Offset voltage. 2.5.2 Motion artifact2.5.3 Electrode polarization; 2.5.3.1 Ohmic overpotential; 2.5.3.2 Concentration overpotential; 2.5.3.3 Activation overpotential; 2.5.4 Liquid junction potential; 2.6 Electrodes Classification; 2.6.1 Noninvasive electrodes; 2.6.1.1 Metal electrodes; 2.6.1.1.1 Limb electrodes; 2.6.1.1.2 Suction electrodes; 2.6.1.1.3 Metal Disc Electrodes; 2.6.1.1.4 EEG electrodes; 2.6.1.1.5 Floating electrodes; 2.6.1.1.5.1 Top-hat electrodes; 2.6.1.1.5.2 Disposable electrodes; 2.6.1.1.6 Dry Electrodes; 2.6.1.2 Flexible electrodes; 2.6.2 Invasive electrodes. 2.6.2.1 Needle and wire electrodes2.6.2.2 Microelectrodes; 2.6.2.2.1 Glass microelectrodes (glass micropipettes); 2.6.2.2.2 Metal microelectrodes; 2.6.2.2.3 Silicon-based microelectrodes; 2.6.3 Electrodes for tissue stimulation; 2.6.3.1 Constant-current stimulation; 2.6.3.2 Constant-voltage stimulation; 2.7 Review the Learning; References; 3 Electrodes for Measurement of Dissolved Gases and Ions Concentration in the Blood Plasma; 3.1 Introduction; 3.2 Gasometry; 3.2.1 Partial pressure of oxygen; 3.2.1.1 The transport of O2 in the blood; 3.2.2 Oxy-hemoglobin saturation. 3.2.3 Partial pressure of carbon dioxide3.2.3.1 The transport of CO2 in the blood; 3.2.4 Activity of H+ ions; 3.2.5 Bicarbonate; 3.2.6 Base excess; 3.3 Electrodes for pO2, pCO2, and pH Measurement; 3.3.1 Potentiometric method; 3.3.2 Amperometric method; 3.3.3 pH measurement; 3.3.3.1 Glass electrode; 3.3.3.2 Combined glass electrode; 3.3.3.3 Measurement of electrolyte concentration; 3.3.4 Electrode for paO2 measurement; 3.3.4.1 Optical fiber-based pO2 microelectrodes; 3.3.4.2 Measurement of electrolyte concentration; 3.3.5 Electrodes for pCO2 measurement; 3.4 Review the Learning; References.
520 _aFocusing on Biomedical Transducers, this book covers the principles of functioning, application examples and new technology solutions. It shows technical and theoretical principles to measure biomedical variables such as arterial blood pressure, blood flow, temperature and CO2 concentration in exhaled air.
650 0 _aTransducers, Biomedical.
650 0 _aMedical instruments and apparatus.
650 1 2 _aBiomedical Engineering.
650 1 2 _aTransducers.
650 2 2 _aElectronics, Medical.
650 7 _aMedical instruments and apparatus.
_2fast
_0(OCoLC)fst01014194
650 7 _aTransducers, Biomedical.
_2fast
_0(OCoLC)fst01154584
856 4 2 _3Publisher description
_uhttp://www.loc.gov/catdir/enhancements/fy1606/2015931607-d.html
942 _2ddc
_cBK