000 03204ntm a2200337 i 4500
001 12102116
005 20241016093433.0
008 150118s2023 ua a f bm 000 0 eng d
040 _aEG-EULC
_cEG-EULC
_erda
041 0 _aeng
_bara
082 0 4 _222
_a617.6342
_bS.H.E
100 1 _aSalah Eldeen, Hatem Tarek
_934097
_eauthor
245 1 0 _aThe effect of nanoparticles incorporation on antimicrobial and bond strength properties of bio-ceramic sealer :
_ban in vitro study /
_cBy Hatem Tarek Salah Eldeen, B.D.S 2017, Faculty of Oral and Dental Medicine, Future University in Egypt
246 1 5 _aتأثير دمج الجسيمات النانوية على خصائص مقاومة الميكروبات وقوة الرابطة للسداد الخزفي الحيوي :
_bدراسة خارج الجسم الحي
264 1 _c2023
300 _a115 pages, 3 pages :
_billustrations (mostly color) ;
_c30 cm
336 _2rdacontent
_atext
337 _2rdamedia
_aunmediated
338 _2rdacarrier
_avolume
500 _aSupervisors, Prof. Wael Hussein Kamel, Professor and Head of Endodontic Department, Faculty of Oral and Dental medicine, Future University in Egypt, Prof. Nehal Ezzat Sabet, Professor of Endodontics, Faculty of Dentistry, Cairo university, Dr. Adel Abdelwahed, Associate professor in Endodontics, Faculty of Oral and Dental medicine, Future University in Egypt
502 _aThesis (M.Sc.)-Future University, Faculty of Oral and Dental Medicine, Department of Endodontics, 2023.
504 _aIncludes bibliographical references.
520 3 _aAH Plus sealer had higher antibacterial effect than Bio-C sealer. The incorporation of bioactive glass nanoparticles improves the antibacterial activity of AH Plus and Bio-C sealer at different time intervals. As regard to the resin-based sealer (AH plus) with or without incoprporation of bioactive glass nanoparticles the highest antibacterial efficacy was recorded at 1 hour while the lowest antibacterial efficacy was recorded after 1 month. As regard to the bioceramic based sealer (Bio-C) with or without incoprporation of bioactive glass nanoparticles the highest antibacterial efficacy was recorded after 1 week while the lowest antibacterial efficacy was recorded after 1 month Regarding the tested root canal sealers, Bio-C with nanoparticles showed the highest push out bond strength compared to other groups followed by bio-c, AH plus with nanoparticles and the least bond strength was AH plus Regarding the sections of the roots, the apical one third showed a significantly lower values in all groups compared to both the middle and coronal thirds, while no significant differences were found between the values of the middle and coronal thirds in all groups Regarding the mode of failure, all tested groups showed significant higher percentage of cohesive failure compared to adhesive and mixed failures
546 _aText in English, abstracts in English and Arabic.
650 0 _aEndodontics
650 0 _aRoot canal therapy
650 0 _aTeeth
_xRoots
856 4 0 _3DSpace electronic resources
_uhttp://repository.fue.edu.eg/xmlui/handle/123456789/6056
942 _cTHESIS
_2ddc
999 _c13190
_d13190