Effect of scan body design on the accuracy of the implant position in implant supported prosthesis / Submitted by Ahmed Safwat Amin Elghazally, (B.D.S. Faculty of Oral and Dental Medicine, Future University in Egypt, 2017); Supervision by Prof. Hussien ElCharkawi, Professor and head of Prosthodontics department, Faculty of Oral & Dental Medicine, Future University in Egypt, Prof. Amro Hosny, Professor of Prosthodontics, Faculty of Dentistry, Cairo University in Egypt, Ass. Prof. Bassem Mohsen, Associate professor of Prosthodontics, Faculty of Oral & Dental Medicine, Future University in Egypt

By: Material type: TextTextLanguage: English Summary language: Arabic Publisher: 2023Description: vi, 74 pages, 3 pages : color illustrations; 22 cmContent type:
  • text
Media type:
  • unmediated
Carrier type:
  • volume
Other title:
  • تأثير تصميم أجسام المسح علي دقة نقل وضع الغرسات تحت التركيبات المحملة عليها [Added title page title]
Subject(s): DDC classification:
  • E.A.E 22 617.692
Online resources: Dissertation note: Thesis (M.Sc.)-Future University in Egypt, Faculty of Oral and Dental Medicine, Department of prosthodontics Department, 2023. Abstract: Effect of Scan body Design on the Accuracy of the Implant Position in Implant Supported Prosthesis This study was conducted to evaluate the accuracy of two types of scan body to evaluate the accuracy of digital impression of implant. In this study a resin model was fabricated and four implant was inserted in the canine and molar area both sides and four standardized long scan bodies were inserted on the top of implant to make the basic reference digital impression then the four long scan bodies were replaced by four short scannable healing abutment and scanning was done then four plastic caps were added above short scannable healing abutment to modify short scan body and scanning was done. The comparison between two types of scan bodies was digitally done and the results showed acceptable high accuracy for both types of scan bodies, however the accuracy of scannable healing abutment with plastic cap was higher than scannable healing abutment without plastic cap.
Star ratings
    Average rating: 0.0 (0 votes)

Submitted by Ahmed Safwat Amin Elghazally, (B.D.S. Faculty of Oral and Dental Medicine, Future University in Egypt, 2017); Supervision by Prof. Hussien ElCharkawi, Professor and head of Prosthodontics department, Faculty of Oral & Dental Medicine, Future University in Egypt, Prof. Amro Hosny, Professor of Prosthodontics, Faculty of Dentistry, Cairo University in Egypt, Ass. Prof. Bassem Mohsen, Associate professor of Prosthodontics, Faculty of Oral & Dental Medicine, Future University in Egypt

Thesis (M.Sc.)-Future University in Egypt, Faculty of Oral and Dental Medicine, Department of prosthodontics Department, 2023.

Includes bibliographical references.

Effect of Scan body Design on the Accuracy of the Implant
Position in Implant Supported Prosthesis
This study was conducted to evaluate the accuracy of two types of scan body to
evaluate the accuracy of digital impression of implant.
In this study a resin model was fabricated and four implant was inserted in the canine
and molar area both sides and four standardized long scan bodies were inserted on the
top of implant to make the basic reference digital impression then the four long scan
bodies were replaced by four short scannable healing abutment and scanning was done
then four plastic caps were added above short scannable healing abutment to modify
short scan body and scanning was done.
The comparison between two types of scan bodies was digitally done and the results
showed acceptable high accuracy for both types of scan bodies, however the accuracy
of scannable healing abutment with plastic cap was higher than scannable healing
abutment without plastic cap.